Thumbnail of page 1Thumbnail of page 2Thumbnail of page 3Thumbnail of page 4
Thumbnail of page 5Thumbnail of page 6Thumbnail of page 7
background image
ORDER NO.
PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan
PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.
PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium
PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936
PIONEER CORPORATION 2001
RRV2510
T ­ ZZY AUG. 2001 Printed in Japan
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Model
DJM-300
DJM-300-S
Type
Power Requirement
The voltage can be converted by
the following method.
KUCXCN
SYLXCN
DJM-300
AC120V
AC110V/120V/220-230V/240V
With the voltage selector
DJ MIXER
DJM-300-S
¶ This service manual should be used together with the following manual(s):
Model No.
Order No.
Remarks
DJM-300/ KUC, SYL
RRV1711
background image
ORDER NO.
PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan
PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A.
PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium
PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936
PIONEER CORPORATION 2001
RRV2510
T ­ ZZY AUG. 2001 Printed in Japan
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Model
DJM-300
DJM-300-S
Type
Power Requirement
The voltage can be converted by
the following method.
KUCXCN
SYLXCN
DJM-300
AC120V
AC110V/120V/220-230V/240V
With the voltage selector
DJ MIXER
DJM-300-S
¶ This service manual should be used together with the following manual(s):
Model No.
Order No.
Remarks
DJM-300/ KUC, SYL
RRV1711
background image
DJM-300, DJM-300-S
2
1. CONTRAST OF MISCELLANEOUS PARTS
Parts marked by "NSP" are generally unavailable because they are not in our Master Spare Parts List.
The
mark found on some component parts indicates the importance of the safety factor of the part.
Therefore, when replacing, be sure to use parts of identical designation.
Screws adjacent to
mark on product are used for disassembly.
Reference Nos. indicate the pages and Nos. in the service manual for the base model.
NOTES:
When ordering resistors, first convert resistance values into code form as shown in the following examples.
Ex.1 When there are 2 effective digits (any digit apart from 0), such as 560 ohm and 47k ohm (tolerance is shown by J=5%,
and K=10%).
Ex.2 When there are 3 effective digits (such as in high precision metal film resistors).
561
473
R50
1R0
5621
560
47k
0.5
1
RD1/4PU
J
RD1/4PU
J
RN2H
K
RS1P
K
56 x 101
47 x 103
R50
1R0
561
473
5.62k
RN1/4PC
F
562 x 101
5621
CONTRAST TABLE ( for DJM-300/ SYLXCN )
DJM-300/KUCXCN and DJM-300/KUC are constructed the same except for the following :
PACKING
P3 - 5
Packing Case
DHG1737
DHG2133
P3 - 8
NSP
Card
DRY1032
Not used
P3 - 9
NSP
Vinyl Bag
DHL1011
Not used
EXTERIOR
P5 - 13
NSP
Rear Panel
DNC1438
DNC1568
FRONT PANEL SECTION
P7 - 25
Control Panel
DNB1068
DNB1091
Part No.
DJM-300/ KUC
Ref. No.
Symbol and Description
Remarks
Mark
DJM-300/ KUCXCN
DJM-300/SYLXCN and DJM-300/SYL are constructed the same except for the following :
PACKING
P3 - 5
Packing Case
DHG1736
DHG2135
EXTERIOR
P5 - 13
NSP
Rear Panel
DNC1437
DNC1569
FRONT PANEL SECTION
P7 - 25
Control Panel
DNB1068
DNB1091
Part No.
DJM-300/ SYL
Ref. No.
Symbol and Description
Remarks
Mark
DJM-300/ SYLXCN
CONTRAST TABLE ( for DJM-300/ KUCXCN )
background image
DJM-300, DJM-300-S
3
DJM-300-S/KUCXCN and DJM-300/KUC are constructed the same except for the following :
PACKING
P3 - 5
Packing Case
DHG1737
DHG2126
P3 - 8
NSP
Card
DRY1032
Not used
P3 - 9
NSP
Vinyl Bag
DHL1011
Not used
EXTERIOR
P5 - 13
NSP
Rear Panel
DNC1438
DNC1566
FRONT PANEL SECTION
P7 - 24
Slider Panel
DAH1825
DAH1892
P7 - 25
Control Panel
DNB1068
DNB1070
Part No.
DJM-300/ KUC
Ref. No.
Symbol and Description
Remarks
Mark
DJM-300-S/ KUCXCN
CONTRAST TABLE ( for DJM-300-S/ KUCXCN )
DJM-300-S/SYLXCN and DJM-300/SYL are constructed the same except for the following :
PACKING
P3 - 5
Packing Case
DHG1736
DHG2128
EXTERIOR
P5 - 13
NSP
Rear Panel
DNC1437
DNC1565
FRONT PANEL SECTION
P7 - 24
Slider Panel
DAH1825
DAH1892
P7 - 25
Control Panel
DNB1068
DNB1070
Part No.
DJM-300/ SYL
Ref. No.
Symbol and Description
Remarks
Mark
DJM-300-S/ SYLXCN
CONTRAST TABLE ( for DJM-300-S/ SYLXCN )

Reviews